#################### PYOTE 5.5.1 session started: Sat Jan 25 18:16:25 2025 #################### filename: C:/Users/u/Downloads/20250118_004505_816x620_G48dBD_0075ms-.csv ==================== file header lines ==================== Tangra v3.7.0.5 Measurments of 2 objects D:\DVTI Captures\20250118_004505_816x620_G48dBD_0075ms.adv Asteroidal Video (ADV2.16), Time: Timestamp Saving During Recording Reversed Gamma, Colour, Measured Band, Integration, Digital Filter, Signal Method, Background Method, Instrumental Delay Corrections, Camera, AAV Integration, First Frame, Last Frame, Reversed Camera Response, Video File Format, Acquisition Delay (ms) 1,00,no,Red,no,NoFilter,AperturePhotometry,AverageBackground,Not Required,DVTI-CAM,,7,777,,ADV, Object, Type, Aperture, Tolerance, FWHM, Measured, StartingX, StartingY, Fixed 1,OccultedStar,2,30,4,66,2,33,yes,378,2,315,2,no 2,GuidingStar,2,30,,2,32,yes,376,6,406,9,no FrameNum,timeInfo,signal-LC1 ==================== end header lines ==================== At reading 00140: time delta to next reading = 1.3500 : likely 17 dropped readings At reading 00415: time delta to next reading = 0.1500 : likely 1 dropped readings ========== Total dropped readings..... 18 ========== Num duplicated readings.... 0 ========== Number timestamp errors.... 0 ========== Number of cadence errors... 2 timeDelta: 0.0749883 seconds per reading timestamp error rate: 0.259% LC2 is the target curve. LC1 is the target curve. The reference curve has been deselected so normalization is disabled. D zone selected: [307, 350] R zone selected: [365, 403] Locate a "D and R" event has been selected Number of candidate solutions: 1716 (using D/R region selections) New solver results... Integer (non-subframe) solution... B:88182.17 A:69398.67 in entryNum units: D: 339 R: 385 noise corr coefs: [1.00] (based on 725 points) sigmaB: 12235.91 noise corr coefs: [1.00] (based on 725 points) sigmaB: 12235.91 Subframe adjusted solution... B:88173.64 A:68969.13 in entryNum units: D: 339 R: 385 D(subframe): 339.0000 R(subframe): 385.0000 in frameNum units: D: 346 R: 392 D(subframe): 346.0000 R(subframe): 392.0000 ... end New solver results Calculating the noise-induced-drop probability - this can take many seconds! Be patient. Error bar report based on 50,000 simulations (units are readings)... loDbar @ .68 ci: -1.1793 hiDbar @ .68 ci: 1.1647 loDbar @ .95 ci: -4.5741 hiDbar @ .95 ci: 4.1642 loDbar @ .9973 ci: -11.8285 hiDbar @ .9973 ci: 10.5093 loDurBar @ .68 ci: -2.2114 hiDurBar @ .68 ci: 2.0585 loDurBar @ .95 ci: -6.4463 hiDurBar @ .95 ci: 5.9727 loDurBar @ .9973 ci: -14.3560 hiDurBar @ .9973 ci: 13.2269 Timestamp validity check ... From timestamps at D and R, calculated 46 reading blocks. From reading blocks, calculated 46 blocks. Timestamps appear valid @ D and R ================= 0.68 containment interval report ================= B: 88173.64 {+/- 454.74} sigmaB: 12235.91 A: 68969.13 {+/- 1799.35} sigmaA: 12070.39 magDrop report: percentDrop: 21.8 magDrop: 0.267 +/- 0.029 (0.68 ci) DNR: 1.57 D: 346.00 {+1.17,-1.17} (frame number) D: [00:45:33.1330] {+0.0879,-0.0879} seconds R: 392.00 {+1.17,-1.17} (frame number) R: [00:45:36.5820] {+0.0879,-0.0879} seconds Duration (R - D): 46.0000 {+2.1350,-2.1350} readings Duration (R - D): 3.4490 {+0.1601,-0.1601} seconds =============== end 0.68 containment interval report =============== ================= 0.95 containment interval report ================= B: 88173.64 {+/- 909.49} sigmaB: 12235.91 A: 68969.13 {+/- 3598.70} sigmaA: 12070.39 magDrop report: percentDrop: 21.8 magDrop: 0.267 +/- 0.058 (0.95 ci) DNR: 1.57 D: 346.00 {+4.37,-4.37} (frame number) D: [00:45:33.1330] {+0.3276,-0.3276} seconds R: 392.00 {+4.37,-4.37} (frame number) R: [00:45:36.5820] {+0.3276,-0.3276} seconds Duration (R - D): 46.0000 {+6.2095,-6.2095} readings Duration (R - D): 3.4490 {+0.4656,-0.4656} seconds =============== end 0.95 containment interval report =============== ================= 0.9973 containment interval report =============== B: 88173.64 {+/- 1364.23} sigmaB: 12235.91 A: 68969.13 {+/- 5398.04} sigmaA: 12070.39 magDrop report: percentDrop: 21.8 magDrop: 0.267 +/- 0.087 (0.9973 ci) DNR: 1.57 D: 346.00 {+11.17,-11.17} (frame number) D: [00:45:33.1330] {+0.8375,-0.8375} seconds R: 392.00 {+11.17,-11.17} (frame number) R: [00:45:36.5820] {+0.8375,-0.8375} seconds Duration (R - D): 46.0000 {+13.7914,-13.7914} readings Duration (R - D): 3.4490 {+1.0342,-1.0342} seconds =============== end 0.9973 containment interval report ============= D frame number: 346.00 D: 0.6800 containment intervals: {+/- 1.18} (readings) D: 0.9500 containment intervals: {+/- 4.57} (readings) D: 0.9973 containment intervals: {+/- 11.83} (readings) R frame number: 392.00 R: 0.6800 containment intervals: {+/- 1.18} (readings) R: 0.9500 containment intervals: {+/- 4.57} (readings) R: 0.9973 containment intervals: {+/- 11.83} (readings) Duration (R - D): 46.0000 readings Duration: 0.6800 containment intervals: {+/- 2.1350} (readings) Duration: 0.9500 containment intervals: {+/- 6.2095} (readings) Duration: 0.9973 containment intervals: {+/- 13.7914} (readings) =============== Summary report for Excel file ===================== This light curve has not been block integrated. The observed drop has an estimated 11.8 sigma level of being a noise-induced-event All times are calculated/reported based on the assumption that timestamps are start-of-exposure times. It is critical that you make appropriate time adjustments when timestamps are NOT start-of-exposure times. If you use the North American Excel Spreadsheet report, all times will be properly corrected for camera delay and reported start-of-exposure times. For other users worldwide, use the appropriate corrections documented in the North American Spreadsheet report form - use the documentation shown on the Corrections Tables tab. magDrop report: percentDrop: 21.8 magDrop: 0.267 +/- 0.058 (0.95 ci) DNR: 1.57 D time: [00:45:33.1330] D: 0.6800 containment intervals: {+/- 0.0879} seconds D: 0.9500 containment intervals: {+/- 0.3276} seconds D: 0.9973 containment intervals: {+/- 0.8375} seconds R time: [00:45:36.5820] R: 0.6800 containment intervals: {+/- 0.0879} seconds R: 0.9500 containment intervals: {+/- 0.3276} seconds R: 0.9973 containment intervals: {+/- 0.8375} seconds Duration (R - D): 3.4490 seconds Duration: 0.6800 containment intervals: {+/- 0.1601} seconds Duration: 0.9500 containment intervals: {+/- 0.4656} seconds Duration: 0.9973 containment intervals: {+/- 1.0342} seconds Enter D and R error bars for each containment interval in Excel spreadsheet without + or - sign (assumed to be +/-) =========== end Summary report for Excel file ===================== Solution 'envelope' in the main plot drawn using 0.95 containment interval error bars fit metrics for LC1 fit metrics === noise-induced-event metric: 1.407 time error bar: +/- 0.3430 seconds DNR: 1.57 fit metrics === B: 88173.64 A: 68969.13 sigmaB: 12235.91 sigmaA: 12070.39 fit metrics === from noise-induced-event test (observed drop: 19204.5) (three sigma drop from noise: 7979.4) gives margin: 11225.1 fit metrics === observed drop has an estimated 11.8 sigma level of being a noise-induced-event fit metrics === magDrop report: percentDrop: 21.8 magDrop: 0.267 +/- 0.058 (0.95 ci) fit metrics === D frame number: 346.0000 fit metrics === R frame number: 392.0000 fit metrics === duration: 3.4490 seconds fit metrics === D time: [00:45:33.1330] fit metrics === R time: [00:45:36.5820] #################### Session ended: Sat Jan 25 18:24:42 2025 ####################